MAG 5100 W - DN80 :: SIEMENS ELECTROMAGNETIC FLOW METER

SKU: 7ME6520-3M
 
MAG 5100W
 
4 - 160mᶾ/h
MCERT and WRAS Approved
High accuracy down to 0.25% of rate (Standard unit 0.5% UKAS Certified).
Bi-directional measurement
Repeatability of 0.1%
Long lasting performance
6 years operation in typical revenue applications
No moving parts that wear and tear
Coned flow tube design for optimal low flow detection (WRc and NSF drinking water approved)
Robust construction built to resist environmental influence

 

  • Pressure Rating
  • Flange Material
  • Liner Material
  • Electrode Material
  • Transmitter
  • Communication
  • Terminal Box
  • £1060.00
  • £1272.00 inc VAT
Qty:  

Description

  • Weight
    13.0000 kg
  • SKU
    7ME6520-3M
 
MAG 5100W
 
MAG 5100 W Magflo Meter, a sensor for all water and waste water applications with MCERTS and WRAS approvals meeting UK EA performance requirements. The increased low-flow accuracy makes it especially useful for leakage detection as well as the more standard applications of water network monitoring and billing, waste water metering and various industrial water measurement applications. It is suitable for direct burial and constant flooding with IP68 potting kit.
 
Typical Applications
 Abstraction - Monitor water collection and avoid excess charges
 Distribution network - Optimize water supply and reduce leakage
 Low flow stability ensures suitability for leakage detection and accurate billing
 Revenue metering - OIML / MID approval for correct billing and monitoring of water consumption
 Irrigation - Rugged design ensures long-term performance for optimal ownership

Specification

     
    MAG 5100 W
     
    The MAG 5100W is an economical electromagnetic flow sensor designed to meet ground water, drinking water, waste water or sludge applications . Used in applications where high accuracy and long service intervals are a must.
    The standard meters are Mains powered 115-230 V AC 50 - 60 Hz (IP67 Rated) but other power options are availble including 11-30V DC/11-24V AC 50/60 Hz .

    Applications:
    Revenue metering - Provide correct billing and monitoring of consumption.
    Flexible power supply makes it useful for leak detection (see BREEAM water leak detection regulations)
    Irrigation - Ensure long-term performance for optimal ownership
    MAG 5100W is optimised for leakage detection and is often used for accurate billing.

    Installation is easy - there is a simple sensor that needs to be bolted in place before operation. Connect the power, the flowmeter comes complete with a compact or remote transmitter with factory mounted cable .
    There will be no need for regular maintenance.
     
    4 - 160mᶾ/h
    High accuracy down to 0.25% of rate (Standard unit 0.5% UKAS Certified).
    Bi-directional measurement
    Repeatability of 0.1%
    Long lasting performance
    6 years operation in typical revenue applications
    No moving parts that wear and tear
    Coned flow tube design for optimal low flow detection (WRc and NSF drinking water approved)
    Robust construction built to resist environmental influence

Downloads