MID2 Electromagnetic Flow Meter:: DN10

SKU: MID2-10
MID2 Electromagnetic Flow Meter:: DN10
Flow: 0.14 - 57 l/min
High accuracy and minimal pressure loss
Flanged connections (DIN or ANSI)
Choice of displays and output options
9-36V DC or 115/230V AC Powered
Optional MID and OIML Approval
  • FLANGES
  • FLANGE MATERIAL
  • LINER
  • ELECTRODES
  • BODY MATERIAL
  • AMPLIFIER
  • MOUNTING
  • COMMS
  • MID Calibration
  • £1662.57
  • £1995.08 inc VAT
Qty:  

Description

  • Weight
    6.0000 kg
  • SKU
    MID2-10
 
MID2 Electromagnetic Flow Meter:: DN10
Flow: 0.14 - 57 l/min
High Accuracy and minimal pressure loss
Flanged connections (DIN or ANSI)
Choice of displays and output options 
9-36V DC or 115/230V AC Powered
Optional MID and OIML Approval
PFA Liner, suitable for -40 to 150°C
Hastelloy C Measuring & Empty Pipe Electrodes
Carbon Steel Housing and flanges (Optional Stianless Steel)
IP67 protection or optional IP68
 
*Various communication protocols
*Integral data logging options available
 
The M2000 amplifier is optionally OIML R49 and MID MI-001 approved
 
The MID2 is a ruggedly constructed electromagnetic flow detector
designed for use in the most demanding applications. Match it with
the M1000 or M2000 LCD amplifier to provide a high performance
flow meter for all conductive fluid applications. Robust construction
with tough epoxy finish (Stainless Body & Flange options)

Specification

    MID2 Electromagnetic Flow Meter:: DN10
    Standard : PN16 Flanges, PFA Liner 
    Hastelloy C Measuring & Empty Pipe Electrodes 
    Carbon Steel Housing, Amplifier/LCD Display & Output Options
    (Build your own model using part code builder above)
     
    Highly accurate; ±0.3% with M1000 or ±0.2% with M2000 amplifier 
    Bi-directional measurement
    Repeatability of 0.1% of full scale
    Engineered for long lasting performance
    No moving parts that wear out
    Robust construction with tough epoxy finish (Stainless options)
     
     
    Amplifiers :
     
    M1000 (up to DN500)
    Accuracy: ±0.3% of measured value
    Display: LCD showing actual flow rate with totalisers and status 
    (min/max alarm, pre-selection, flow direction, empty pipe error).
    Digital Outputs: 2x Open collector, 1x relay
    Analogue Outputs: 0/4 - 20 mA, 0 - 10mA
    Interface: Standard - ModBus RTU RS232/RS485, ModBus/TCP
                      Optional - HART, M-Bus
    Power Supply: 9 - 36 VDC or 92 - 275 VAC 
    Housing: IP67 Powder coated die-cast aluminium
    Compact mounting on detector or remote mount kits.
    Data logger: Internal data logger (30 000 measuring values)
                           Accessable by additional software and communication cable

    M2000 (all sizes)
    Accuracy: ±0.2% of measured value
    Display: LCD showing actual flow rate with totalisers and status 
    (min/max alarm, pre-selection, flow direction, empty pipe error).
    Digital Outputs: 4x Open collector, 2x relay
    Analogue Outputs: 0/4 - 20 mA, 0 - 10mA
    Interface: Standard - ModBus RTU RS232
                      Optional - RS485, HART, Profibus DP, M-Bus
    Power Supply: 9 - 36 VDC or 85 - 265 VAC
    Housing: IP67 Powder coated die-cast aluminium
    Compact mounting on detector or remote mount kits.
    Data logger: Optional 10 000 measuring values (requires additional memory card)
                           Accessable by additional software and communication cable
     
    Dimensions
     

Downloads